New to Claude Skills? Learn how to install them →

mukul975 on GitHub

Detecting Stuxnet-Style Attacks

Free

Advanced detection for cyber-physical threats in OT environments.

Get this skill

Free · Opens the source repo

What Detecting Stuxnet-Style Attacks does

Detecting Stuxnet-Style Attacks is a specialized skill designed to identify sophisticated cyber-physical threats that emulate the Stuxnet attack methodology. This skill focuses on monitoring programmable logic controllers (PLCs) for unauthorized modifications and detecting discrepancies between PLC logic and actual physical process behavior. It is particularly relevant for organizations operating in critical sectors such as nuclear, chemical, and other essential infrastructure where the integrity of operational technology (OT) is paramount.

The skill leverages PLC logic integrity monitoring and physics-based anomaly detection to provide a robust defense against advanced persistent threats (APTs) targeting industrial control systems (ICS) and supervisory control and data acquisition (SCADA) environments. Users must have a comprehensive understanding of the Stuxnet attack chain and the MITRE ATT&CK framework for ICS to effectively implement this skill. It requires a detailed baseline of PLC programs and continuous monitoring to detect any unauthorized changes that could indicate a compromise.

To utilize this skill, users will map detection opportunities across the stages of a Stuxnet-style attack, from initial access through to process manipulation. Each stage includes specific techniques, detection methods, and indicators to look for, enabling users to establish a thorough monitoring strategy. The skill also emphasizes the importance of integrating various monitoring tools and practices to create a defense-in-depth approach against potential threats.

This skill is essential for cybersecurity professionals tasked with safeguarding critical OT systems from advanced cyber threats. By implementing this skill, organizations can enhance their detection capabilities and respond effectively to potential attacks that could disrupt physical processes and compromise safety.

When to use it

Use this skill when implementing advanced threat detection for high-value OT targets or when investigating suspected process anomalies that may indicate cyber-physical attacks.

When not to use it

This skill is not suitable for basic OT intrusion detection or for malware analysis of Stuxnet samples, as it focuses specifically on detecting complex attack patterns rather than general security measures.

What you can build with it

Monitoring Critical Infrastructure

Utilize this skill to continuously monitor PLCs in critical infrastructure environments, ensuring any unauthorized changes are detected promptly.

Investigating Anomalies in Process Behavior

Employ this skill when investigating discrepancies between PLC logic and physical process behavior, helping to identify potential cyber threats.

Implementing Defense-in-Depth Strategies

Integrate this skill into a broader cybersecurity strategy to enhance defenses against advanced persistent threats targeting operational technology.

How to install Detecting Stuxnet-Style Attacks

View source

1. Install with the skills CLI

npx skills add mukul975/anthropic-cybersecurity-skills/detecting-stuxnet-style-attacks --agent claude-code

2. Or install it manually

Download the skill folder and drop it into ~/.claude/skills/ for all projects, or .claude/skills/ to scope it to one repo. Restart Claude Code so it picks up the new skill.

Anthropic's agentic coding CLI, and the reference implementation of Agent Skills. Drop a skill folder into ~/.claude/skills and Claude Code loads it automatically whenever a task matches the skill's description. Claude Code docs

Inside SKILL.md

Written by mukul975

Detecting Stuxnet-Style Attacks

When to Use

  • When implementing advanced threat detection for high-value OT targets (nuclear, chemical, critical infrastructure)
  • When building detection for APT-style attacks targeting PLC logic and process manipulation
  • When establishing PLC logic integrity monitoring to detect unauthorized modifications
  • When investigating suspected process anomalies that may indicate cyber-physical attacks
  • When designing defense-in-depth strategies against nation-state level OT threats

Do not use for basic OT intrusion detection (see detecting-attacks-on-scada-systems), for malware analysis of Stuxnet samples (see malware reverse engineering skills), or for PLC programming and logic development.

Prerequisites

  • Detailed understanding of the Stuxnet attack chain and MITRE ATT&CK for ICS framework
  • PLC logic backup repository with known-good baseline copies of all PLC programs
  • Engineering workstation monitoring (EDR with OT awareness)
  • Physics-based process models for the controlled physical process
  • Network monitoring for industrial protocol traffic analysis

Workflow

Step 1: Understand the Stuxnet Attack Chain

Map detection opportunities across the multi-stage Stuxnet-style attack chain.

# Stuxnet-Style Attack Chain and Detection Points
attack_chain:
  stage_1_initial_access:
    technique: "USB-borne malware targeting air-gapped network"
    mitre_ics: "T0847 - Replication Through Removable Media"
    detection:
      - "USB device connection logging on engineering workstations"
      - "Removable media scanning with OT-approved AV"
      - "Application allowlisting blocking unauthorized executables"
      - "Windows autorun disabled via Group Policy"
    indicators:
      - "New USB device connections to engineering workstations"
      - "Execution of unsigned binaries from removable media"
      - "LNK file exploitation patterns"

  stage_2_lateral_movement:
    technique: "Exploitation of Windows vulnerabilities for network propagation"
    mitre_ics: "T0866 - Exploitation of Remote Services"
    detection:
      - "Network IDS detecting exploit traffic (MS08-067, MS10-061)"
      - "Unusual SMB traffic between engineering workstations"
      - "Windows event logs showing privilege escalation"
      - "New scheduled tasks or services created"
    indicators:
      - "Lateral movement between Level 3-4 Windows systems"
      - "WMI/PsExec execution from unexpected sources"
      - "Pass-the-hash authentication patterns"

  stage_3_ews_compromise:
    technique: "Compromise of engineering workstation with PLC programming software"
    mitre_ics: "T0862 - Supply Chain Compromise (Step-7 hooking)"
    detection:
      - "File integrity monitoring on Step-7/TIA Portal directories"
      - "DLL injection detection in PLC programming software"
      - "Monitoring s7otbxdx.dll for Stuxnet-specific hook"
      - "Unexpected modifications to PLC project files"
    indicators:
      - "Modified DLLs in Siemens STEP 7 installation directory"
      - "Rootkit hiding files on engineering workstation"
      - "PLC programming software behaving abnormally"

  stage_4_plc_logic_modification:
    technique: "Injecting malicious OB/FC blocks into PLC program"
    mitre_ics: "T0839 - Module Firmware / T0833 - Modify Control Logic"
    detection:
      - "PLC logic integrity comparison against known-good baseline"
      - "S7comm upload/download traffic from unauthorized sources"
      - "New OB/FC/FB blocks appearing in PLC program"
      - "Modification of OB1 (main scan) or OB35 (cyclic interrupt)"
    indicators:
      - "PLC program block count changes"
      - "PLC program size changes"
      - "Upload of unknown program blocks"

  stage_5_process_manipulation:
    technique: "Manipulating physical process while spoofing sensor readings"
    mitre_ics: "T0836 - Modify Parameter / T0856 - Spoof Reporting Message"
    detection:
      - "Physics-based anomaly detection (process model deviation)"
      - "Cross-validation of independent sensors"
      - "Vibration analysis and mechanical signature monitoring"
      - "Comparison of PLC-reported values vs independent measurements"
    indicators:
      - "Motor/pump operating outside normal parameters"
      - "Sensor readings diverging from physics model predictions"
      - "Process efficiency metrics deviating unexpectedly"

Step 2: Implement PLC Logic Integrity Monitoring

Continuously monitor PLC program integrity by comparing running logic against known-good baselines.

#!/usr/bin/env python3
"""PLC Logic Integrity Monitor.

Periodically retrieves PLC program block information and compares
against known-good baselines to detect unauthorized modifications
(Stuxnet-style logic injection).
"""

import hashlib
import json
import sys
import time
from dataclasses import dataclass, field, asdict
from datetime import datetime


@dataclass
class PLCBlock:
    """Represents a PLC program block."""
    block_type: str  # OB, FC, FB, DB
    block_number: int
    name: str
    size_bytes: int
    checksum: str
    last_modified: str
    author: str = ""


@dataclass
class IntegrityAlert:
    alert_id: str
    timestamp: str
    severity: str
    plc_name: str
    plc_ip: str
    alert_type: str
    description: str
    baseline_value: str
    current_value: str
    mitre_technique: str


class PLCIntegrityMonitor:
    """Monitors PLC program integrity against baselines."""

    def __init__(self):
        self.baselines = {}  # plc_name -> list of PLCBlock
        self.alerts = []
        self.alert_counter = 1

    def load_baseline(self, plc_name, baseline_file):
        """Load known-good PLC program baseline."""
        with open(baseline_file) as f:
            data = json.load(f)
        blocks = [PLCBlock(**b) for b in data.get("blocks", [])]
        self.baselines[plc_name] = {
            "blocks": {f"{b.block_type}{b.block_number}": b for b in blocks},
            "total_blocks": len(blocks),
            "loaded_at": datetime.now().isoformat(),
        }
        print(f"[*] Loaded baseline for {plc_name}: {len(blocks)} blocks")

    def check_integrity(self, plc_name, plc_ip, current_blocks):
        """Compare current PLC program against baseline."""
        baseline = self.baselines.get(plc_name)
        if not baseline:
            print(f"[WARN] No baseline for {plc_name}")
            return

        baseline_blocks = baseline["blocks"]
        current_block_map = {f"{b.block_type}{b.block_number}": b for b in current_blocks}

        # Check 1: New blocks added (potential logic injection)
        for key, block in current_block_map.items():
            if key not in baseline_blocks:
                self.alerts.append(IntegrityAlert(
                    alert_id=f"INT-{self.alert_counter:04d}",
                    timestamp=datetime.now().isoformat(),
                    severity="critical",
                    plc_name=plc_name,
                    plc_ip=plc_ip,
                    alert_type="NEW_BLOCK_DETECTED",
                    description=(
                        f"New program block {key} ({block.name}) found in PLC "
                        f"that does not exist in baseline. Size: {block.size_bytes} bytes."
                    ),
                    baseline_value="Block does not exist in baseline",
                    current_value=f"{key}: {block.size_bytes} bytes, checksum {block.checksum}",
                    mitre_technique="T0839 - Module Firmware / T0833 - Modify Control Logic",
                ))
                self.alert_counter += 1

        # Check 2: Blocks removed
        for key in baseline_blocks:
            if key not in current_block_map:
                self.alerts.append(IntegrityAlert(
                    alert_id=f"INT-{self.alert_counter:04d}",
                    timestamp=datetime.now().isoformat(),
                    severity="high",
                    plc_name=plc_name,
                    plc_ip=plc_ip,
                    alert_type="BLOCK_REMOVED",
                    description=f"Program block {key} removed from PLC",
                    baseline_value=f"{key}: {baseline_blocks[key].size_bytes} bytes",
                    current_value="Block not found",
                    mitre_technique="T0833 - Modify Control Logic",
                ))
                self.alert_counter += 1

        # Check 3: Block content modified (checksum mismatch)
        for key in baseline_blocks:
            if key in current_block_map:
                baseline_block = baseline_blocks[key]
                current_block = current_block_map[key]

                if baseline_block.checksum != current_block.checksum:
                    self.alerts.append(IntegrityAlert(
                        alert_id=f"INT-{self.alert_counter:04d}",
                        timestamp=datetime.now().isoformat(),
                        severity="critical",
                        plc_name=plc_name,
                        plc_ip=plc_ip,
                        alert_type="BLOCK_MODIFIED",
                        description=(
                            f"Program block {key} checksum mismatch. "
                            f"Logic has been modified since baseline was established."
                        ),
                        baseline_value=f"Checksum: {baseline_block.checksum}, Size: {baseline_block.size_bytes}",
                        current_value=f"Checksum: {current_block.checksum}, Size: {current_block.size_bytes}",
                        mitre_technique="T0833 - Modify Control Logic",
                    ))
                    self.alert_counter += 1

        # Check 4: Block count change
        if len(current_blocks) != baseline["total_blocks"]:
            self.alerts.append(IntegrityAlert(
                alert_id=f"INT-{self.alert_counter:04d}",
                timestamp=datetime.now().isoformat(),
                severity="high",
                plc_name=plc_name,
                plc_ip=plc_ip,
                alert_type="BLOCK_COUNT_CHANGE",
                description=f"Total block count changed from {baseline['total_blocks']} to {len(current_blocks)}",
                baseline_value=str(baseline["total_blocks"]),
                current_value=str(len(current_blocks)),
                mitre_technique="T0833 - Modify Control Logic",
            ))
            self.alert_counter += 1

    def generate_report(self):
        """Generate integrity monitoring report."""
        print(f"\n{'='*70}")
        print("PLC LOGIC INTEGRITY MONITORING REPORT")
        print(f"{'='*70}")
        print(f"Baselines loaded: {len(self.baselines)}")
        print(f"Alerts: {len(self.alerts)}")

        for a in self.alerts:
            print(f"\n  [{a.severity.upper()}] {a.alert_type}")
            print(f"    PLC: {a.plc_name} ({a.plc_ip})")
            print(f"    {a.description}")
            print(f"    Baseline: {a.baseline_value}")
            print(f"    Current: {a.current_value}")
            print(f"    MITRE: {a.mitre_technique}")


if __name__ == "__main__":
    monitor = PLCIntegrityMonitor()
    print("PLC Logic Integrity Monitor")
    print("Load baselines and call check_integrity() periodically")

Step 3: Deploy Physics-Based Process Anomaly Detection

Monitor physical process behavior using models that predict expected sensor values based on the laws of physics. Deviations indicate either equipment failure or cyber-physical attack.

#!/usr/bin/env python3
"""Physics-Based Cyber-Physical Attack Detector.

Uses simplified physics models to detect process manipulation
attacks where the attacker modifies the physical process while
spoofing sensor readings (the core Stuxnet attack pattern).
"""

import math
from dataclasses import dataclass
from datetime import datetime


@dataclass
class PhysicsAlert:
    timestamp: str
    severity: str
    alert_type: str
    sensor_tag: str
    reported_value: float
    predicted_value: float
    deviation_percent: float
    description: str


class CentrifugePhysicsModel:
    """Physics model for a centrifuge system (Stuxnet target analog).

    Detects manipulation by cross-correlating:
    - Motor frequency (Hz) vs reported RPM
    - RPM vs vibration signature
    - Power consumption vs rotational speed
    """

    def __init__(self, rated_rpm=1200, rated_frequency=50, rated_power_kw=75):
        self.rated_rpm = rated_rpm
        self.rated_frequency = rated_frequency
        self.rated_power_kw = rated_power_kw
        self.alerts = []

    def check_frequency_rpm_correlation(self, frequency_hz, reported_rpm):
        """Verify motor frequency matches reported RPM.

        For an induction motor: RPM = 120 * frequency / poles
        If RPM is being spoofed, it won't match the actual frequency.
        """
        # Assuming 4-pole motor with typical 3% slip
        expected_rpm = (120 * frequency_hz / 4) * 0.97
        deviation = abs(reported_rpm - expected_rpm) / expected_rpm * 100

        if deviation > 5.0:
            self.alerts.append(PhysicsAlert(
                timestamp=datetime.now().isoformat(),
                severity="critical",
                alert_type="FREQUENCY_RPM_MISMATCH",
                sensor_tag="MOTOR.RPM vs VFD.FREQ",
                reported_value=reported_rpm,
                predicted_value=round(expected_rpm, 1),
                deviation_percent=round(deviation, 1),
                description=(
                    f"Motor RPM ({reported_rpm}) does not match VFD frequency "
                    f"({frequency_hz} Hz). Expected ~{expected_rpm:.0f} RPM. "
                    f"Possible RPM sensor spoofing while frequency is manipulated."
                ),
            ))

    def check_power_speed_correlation(self, rpm, power_kw):
        """Verify power consumption matches rotational speed.

        Power scales approximately with RPM^3 for centrifugal loads.
        """
        speed_ratio = rpm / self.rated_rpm
        expected_power = self.rated_power_kw * (speed_ratio ** 3)
        deviation = abs(power_kw - expected_power) / max(expected_power, 0.1) * 100

        if deviation > 15.0:
            self.alerts.append(PhysicsAlert(
                timestamp=datetime.now().isoformat(),
                severity="high",
                alert_type="POWER_SPEED_MISMATCH",
                sensor_tag="MOTOR.POWER vs MOTOR.RPM",
                reported_value=power_kw,
                predicted_value=round(expected_power, 1),
                deviation_percent=round(deviation, 1),
                description=(
                    f"Power consumption ({power_kw} kW) inconsistent with RPM ({rpm}). "
                    f"Expected ~{expected_power:.1f} kW. May indicate hidden speed changes."
                ),
            ))

    def check_vibration_anomaly(self, rpm, vibration_mm_s):
        """Check if vibration signature is consistent with operating speed.

        Abnormal vibration at reported 'normal' speed may indicate actual
        speed is different from what sensors report.
        """
        # Normal vibration increases linearly with speed for balanced rotor
        speed_ratio = rpm / self.rated_rpm
        expected_vibration = 2.0 * speed_ratio  # mm/s baseline
        deviation = abs(vibration_mm_s - expected_vibration) / max(expected_vibration, 0.1) * 100

        if vibration_mm_s > 7.0:  # ISO 10816 alert threshold
            self.alerts.append(PhysicsAlert(
                timestamp=datetime.now().isoformat(),
                severity="critical",
                alert_type="ABNORMAL_VIBRATION",
                sensor_tag="MOTOR.VIBRATION",
                reported_value=vibration_mm_s,
                predicted_value=round(expected_vibration, 1),
                deviation_percent=round(deviation, 1),
                description=(
                    f"Vibration ({vibration_mm_s} mm/s) at ISO alert level while "
                    f"RPM reports normal ({rpm}). Actual speed may differ from reported."
                ),
            ))

    def report(self):
        if self.alerts:
            print(f"\n{'='*60}")
            print("PHYSICS-BASED ANOMALY DETECTION ALERTS")
            print(f"{'='*60}")
            for a in self.alerts:
                print(f"\n  [{a.severity.upper()}] {a.alert_type}")
                print(f"    {a.description}")
                print(f"    Reported: {a.reported_value} | Predicted: {a.predicted_value}")
                print(f"    Deviation: {a.deviation_percent}%")


if __name__ == "__main__":
    model = CentrifugePhysicsModel(rated_rpm=1200, rated_frequency=50, rated_power_kw=75)

    # Normal operation - no alerts expected
    model.check_frequency_rpm_correlation(50.0, 1164)
    model.check_power_speed_correlation(1164, 72.0)

    # Stuxnet-style attack: frequency increased but RPM spoofed as normal
    model.check_frequency_rpm_correlation(84.0, 1164)  # freq up, RPM spoofed
    model.check_power_speed_correlation(1164, 180.0)    # power reveals true speed

    model.report()

Key Concepts

TermDefinition
Cyber-Physical AttackAttack that manipulates both the cyber system (PLC logic, sensor readings) and the physical process simultaneously
Logic InjectionInserting malicious code blocks into PLC programs to alter physical process behavior
Sensor SpoofingReplaying or fabricating sensor readings to hide process manipulation from operators
Physics-Based DetectionUsing mathematical models of physical processes to detect when reported sensor values are inconsistent with actual physics
PLC Logic BaselineKnown-good copy of PLC program blocks (OB, FC, FB, DB) used for integrity comparison
Air-Gap BridgingTechnique of crossing air-gapped networks via USB drives, as used by Stuxnet's initial access method

Tools & Systems

  • Claroty xDome: Continuous PLC logic monitoring with baseline comparison and change detection
  • SIGA OT Solutions: Physical signal monitoring at the electrical level for detecting process manipulation
  • Nozomi Guardian: OT monitoring with PLC program change detection capabilities
  • Siemens SINEMA Remote Connect: Secure remote access with PLC project version tracking

Output Format

Stuxnet-Style Attack Detection Report
========================================
Monitored PLCs: [N]
Monitoring Period: YYYY-MM-DD to YYYY-MM-DD

PLC INTEGRITY:
  Baselines verified: [N]/[N]
  Logic modifications detected: [N]
  New blocks detected: [N]

PHYSICS ANOMALIES:
  Sensor correlation violations: [N]
  Process model deviations: [N]

ENGINEERING WORKSTATION:
  Unauthorized modifications: [N]
  USB connections: [N]

Frequently asked questions about Detecting Stuxnet-Style Attacks

Similar skills