MDR 2017/745 Specialist
FreeExpert guidance for EU medical device compliance.
Free · Opens the source repo
What MDR 2017/745 Specialist does
The MDR 2017/745 Specialist skill provides in-depth support for navigating the complexities of EU medical device regulations. It is designed for professionals involved in the development, compliance, and regulatory oversight of medical devices. This skill offers a structured approach to understanding and implementing the requirements set forth in the MDR, ensuring that users can effectively manage compliance and documentation processes.
With a focus on core competencies such as classification and risk assessment, technical documentation requirements, clinical evidence management, and post-market surveillance, this skill serves as a comprehensive resource for medical device manufacturers and regulatory affairs specialists. Users can access detailed frameworks for classification decisions, technical file preparation, and clinical evidence strategies, enabling them to streamline their compliance efforts and reduce the risk of regulatory issues.
Additionally, the skill includes guidance on implementing a Unique Device Identification (UDI) system and managing interactions with Notified Bodies, which are critical for ensuring compliance throughout the product lifecycle. By leveraging this skill, users can conduct systematic gap analyses and develop transition plans to align existing products with the new MDR requirements, thus facilitating a smoother path to market.
Overall, the MDR 2017/745 Specialist skill is an essential tool for anyone involved in the medical device industry looking to enhance their understanding of regulatory requirements and improve their compliance processes.
When to use it
Use this skill when preparing for MDR compliance assessments, classifying medical devices, or developing technical documentation.
When not to use it
This skill may not be suitable for users outside the medical device industry or for those seeking general regulatory guidance unrelated to MDR.
What you can build with it
Preparing for MDR Compliance Assessment
Use this skill to ensure your medical device meets all MDR requirements before assessment.
Developing Technical Documentation
Leverage the structured documentation framework to prepare comprehensive technical files for your devices.
Conducting Clinical Evidence Review
Utilize the clinical evidence pathways to determine the adequacy of existing data for your medical devices.
How to install MDR 2017/745 Specialist
View source1. Install with the skills CLI
npx skills add davila7/claude-code-templates/mdr-745-specialist --agent claude-code2. Or install it manually
Download the skill folder and drop it into ~/.claude/skills/ for all projects, or .claude/skills/ to scope it to one repo. Restart Claude Code so it picks up the new skill.
Anthropic's agentic coding CLI, and the reference implementation of Agent Skills. Drop a skill folder into ~/.claude/skills and Claude Code loads it automatically whenever a task matches the skill's description. Claude Code docs
Inside SKILL.md
Written by davila7Senior MDR 2017/745 Specialist and Consultant
Expert-level EU MDR 2017/745 compliance specialist with comprehensive knowledge of medical device regulation requirements, technical documentation, clinical evidence, and post-market surveillance obligations.
Core MDR Competencies
1. MDR Classification and Risk Assessment
Provide expert guidance on device classification under MDR Annex VIII and conformity assessment route selection.
Classification Decision Framework:
-
Preliminary Classification Assessment
- Apply MDR Annex VIII classification rules
- Consider device duration, invasiveness, and body system interaction
- Evaluate software classification per MDCG 2019-11
- Decision Point: Determine appropriate classification class (I, IIa, IIb, III)
-
Classification Justification
- Document classification rationale per references/mdr-classification-guide.md
- Consider borderline cases and MDCG guidance
- Evaluate combination device implications
- Validate classification with Notified Body consultation
-
Conformity Assessment Route Selection
- Class I: Self-certification under Annex II
- Class IIa: Module C2 + Annex V (Notified Body involvement)
- Class IIb: Module B + C or D (Type examination + production)
- Class III: Module B + C or D (Full quality assurance)
2. Technical Documentation Requirements (Annex II & III)
Ensure comprehensive technical file preparation meeting all MDR documentation requirements.
Technical Documentation Structure:
ANNEX II TECHNICAL DOCUMENTATION
├── General Information
│ ├── Device identification and UDI-DI
│ ├── Manufacturer and authorized representative info
│ ├── Intended purpose and clinical condition
│ └── Device description and variants
├── Information to be Supplied by Manufacturer
│ ├── Label and instructions for use
│ ├── Clinical evaluation and post-market clinical follow-up
│ ├── Risk management documentation
│ └── Product verification and validation
├── Design and Manufacturing Information
│ ├── Quality management system documentation
│ ├── Design and development process
│ ├── Manufacturing process description
│ └── Identification and traceability procedures
└── General Safety and Performance Requirements
├── Solutions adopted for GSPR compliance
├── Benefit-risk analysis and risk management
├── Product lifecycle and post-market surveillance
└── Clinical evidence and evaluation
3. Clinical Evidence Requirements (Annex XIV)
Manage comprehensive clinical evidence strategies ensuring MDR compliance and scientific rigor.
Clinical Evidence Pathway Selection:
-
Literature-Based Evidence
- Systematic literature review methodology
- Appraisal of clinical data per MEDDEV 2.7/1 rev.4
- Gap analysis and additional evidence requirements
- Decision Point: Determine if literature is sufficient or clinical investigation required
-
Clinical Investigation Requirements
- For significant changes or novel devices
- For Class III implantable devices (Article 61)
- Clinical investigation plan development
- Ethics committee and competent authority approvals
-
Post-Market Clinical Follow-up (PMCF)
- PMCF Plan development per Annex XIV Part B
- PMCF Evaluation Report (PMCF-ER) preparation
- Clinical evaluation report updating requirements
- Integration with post-market surveillance system
4. UDI System Implementation (Article 27)
Implement comprehensive Unique Device Identification system meeting MDR requirements and EUDAMED integration.
UDI Implementation Workflow:
-
UDI Strategy Development
- UDI-DI assignment for device variants
- UDI-PI requirements for higher risk devices
- EUDAMED registration timeline planning
- Labeling compliance verification
-
EUDAMED Registration
- Actor registration (manufacturers, authorized representatives)
- Device registration and UDI-DI assignment
- Certificate registration (Notified Body certificates)
- Clinical investigation and serious incident reporting
MDR Compliance Management
Gap Analysis and Transition Planning
Conduct systematic gap assessments against current MDR requirements and develop comprehensive transition strategies.
Gap Analysis Framework:
-
Current State Assessment
- Existing QMS compliance evaluation
- Technical documentation gap identification
- Clinical evidence adequacy assessment
- Post-market surveillance system review
-
MDR Requirement Mapping
- For existing devices: Legacy directive vs. MDR requirements
- For new devices: Full MDR compliance roadmap
- For software: Software-specific MDR requirements per MDCG guidance
- Resource and timeline impact assessment
Post-Market Surveillance (Chapter VII)
Establish robust post-market surveillance systems meeting MDR requirements for continuous safety monitoring.
PMS System Components:
- PMS Plan development per Article 84
- Periodic Safety Update Report (PSUR) preparation
- Serious incident reporting to competent authorities
- Field safety corrective actions (FSCA) management
- Trend reporting and signal detection
Economic Operator Obligations
Ensure compliance with expanded economic operator responsibilities under MDR.
Key Obligations Management:
- Manufacturer obligations (Article 10)
- Authorized representative duties (Article 11)
- Importer responsibilities (Article 13)
- Distributor obligations (Article 14)
- Person responsible for regulatory compliance (Article 15)
Notified Body Interface
Notified Body Selection and Management
Provide strategic guidance on Notified Body selection and relationship management throughout the conformity assessment process.
Notified Body Engagement Strategy:
-
Selection Criteria Assessment
- Technical competency evaluation
- Capacity and timeline considerations
- Geographic scope and market access
- Fee structure and commercial terms
-
Pre-submission Activities
- Pre-submission meetings and consultations
- Technical documentation readiness assessment
- Timeline and milestone planning
- Decision Point: Determine submission readiness and timing
Audit and Assessment Management
Coordinate Notified Body audits and assessments ensuring successful outcomes and certificate maintenance.
Audit Preparation Protocol:
- Documentation preparation and organization
- Personnel training and role assignment
- Facility readiness and compliance verification
- Mock audit execution and improvement implementation
Regulatory Intelligence and Updates
MDR Guidance Monitoring
Maintain current awareness of evolving MDR guidance and regulatory expectations.
Guidance Tracking System:
- MDCG guidance monitoring and impact assessment
- Notified Body guidance evaluation and implementation
- Competent authority positions and national implementations
- Industry best practices and lessons learned integration
Resources
scripts/
mdr-gap-analysis.py: Automated MDR compliance gap assessment toolclinical-evidence-tracker.py: Clinical evidence requirement monitoringudeudi-compliance-checker.py: UDI and EUDAMED compliance verificationpms-reporting-automation.py: Post-market surveillance report generation
references/
mdr-classification-guide.md: Comprehensive device classification frameworktechnical-documentation-templates.md: Annex II and III documentation templatesclinical-evidence-requirements.md: Clinical evaluation and PMCF guidancenotified-body-selection-criteria.md: NB evaluation and selection frameworkmdcg-guidance-library.md: Current MDCG guidance compilation
assets/
mdr-templates/: Technical file, clinical evaluation, and PMS plan templatesgap-analysis-checklists/: MDR compliance assessment toolseudamed-forms/: EUDAMED registration and reporting templatestraining-materials/: MDR training presentations and compliance guides
Frequently asked questions about MDR 2017/745 Specialist
Similar skills
Contract Review
Simplify contract analysis for small businesses.
Vendor Agreement Status
Streamline vendor agreement management across systems.
NDA Triage
Streamline your NDA screening process efficiently.
Contract Review
Streamline contract analysis against your negotiation playbook.
Meeting Briefing
Prepare structured legal meeting briefings and track actions.
Legal Risk Assessment
Evaluate and classify legal risks systematically.